Data Sheet DM-III MULTITEST Power Quality Recorder Amprobe's full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today's demanding electrical environments. POWER QUALITY ANALYZER/DATA LOGGER - True RMS (TRMS) - Measures & Records Broad Spectrum of Power Quality Parameters * AC Current * AC Voltage to 600 V * Sags and Surges * Harmonics * Active, Reactive and Apparent * Power No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: $500 MSLP limit) * Peak Demand * Power Factor * Frequency * Phase Sequence - Compatible with wide range of current transducers - Works with single and three phase - Detects & records Sags and Surges - Displacement power factor for power factor correction determination - Built in scope displays waveforms - Phase sequence indication - Records up to 64 parameters - Selectable fundamental frequency - Special data compression system - Download capabilities, Windows compatible - A complete kit: 1000A Clamp, Voltage Leads, Ground Probes & Leads, PC software & cable continued on next page 600V Amprobe(R) Test Tools www.Amprobe.com Data Sheet INSULATION TESTER FUNCTIONS: -- Tests insulation integrity of wires, cables, transformers & electrical motors -- Selectable test voltages up to 1000 V -- Programmable timer to perform the Dielectric Absorption Ratio Test -- Sensitive Ohmmeter for checking resistance of motor windings -- Selectable polarization of ohmmeter for checking grounding continuity -- Automatic voltmeter protects against misuse on hazardous energized systems GROUND RESISTANCE & RESISTIVITY FUNCTIONS: -- Three measuring modes: * 2 point continuity/resistance test * 3 point Fall of Potential test * 4 point Earth Resistivity measurement -- Automatic voltage measurement prevents false measurements -- Automatically applies three testing frequencies for the most accurate readings -- Detects faulty test conditions such as poor soil conditions and input noise PHASE SEQUENCE -- Phase sequence indication -- Frequency measurement -- Phase-to-Phase voltage measurement Amprobe(R) Test Tools Data Sheet DM-III MULTITEST Power Quality Recorder Specifications Supplied Current Transducer Input accuracy AC Current AC Voltage including Sags and Surges Harmonics Power Energy Peak Demand Power Factor Frequency measurement Phase sequence Co-generation Selectable Fundamental Frequencies Available Recording Time DM-CT-DMA; 1000A Standard CT, 2" internal diameter CT (0.5% Rdg + 2 LSD) DM-CT-100: 0.5A to 100A DM-CT-HTA: 5 - 1000A AM-FLEX33: Selectable: 5 - 1000A or 15 - 3000A 0 - 600V THD, DC and individual up to 49th Working (W), Reactive (VAR) and Apparent (VA) (1.0% Rdg + 2 LSD) Working (kWh), Reactive (VARh) and Apparent (VAh) (1.0% Rdg + 2 LSD) KW (1.0% Rdg + 2 LSD) 0.00 - 1.00 57 to 63.6 Hz at 60Hz fundamental; 47 to 53 Hz at 50Hz fundamental; (1.0% Rdg + 2 LSD) 1-2-3 Computes incoming and outgoing energy 50/60 Hz Several hours to several years depending on setup Megohmmeter Insulation resistance with 50 VDC test voltage Insulation resistance with 100 VDC test voltage Insulation resistance with 250 VDC test voltage Insulation resistance with 500 VDC test voltage Insulation resistance with 1000 VDC test voltage Low Resistance (without timer) Low Resistance (with timer) Range Accuracy 0.01 - 19.99, 49.9 49.9 - 99.9M (2% Reading + 2 digits) (5% Reading + 2 digits) 0.01 - 19.99, 99.9 99.9 - 199.9M (2% Reading + 2 digits) (5% Reading + 2 digits) 0.01 - 19.99, 199.9, 249 249 - 499 M (2% Reading + 2 digits) (5% Reading + 2 digits) 0.01 - 19.99, 199.9, 499 499 - 999 M (2% Reading + 2 digits) (5% Reading + 2 digits) 0.01 - 19.99, 199.9, 999 999 - 1999 M 0.01 - 19.99, 99.9 0.01 - 9.99 (2% Reading + 2 digits) (5% Reading + 2 digits) (2% Reading + 2 digits) (2% Reading + 2 digits) Ground Resistance Ground resistance Ground resistivity Range 0 - 19.99, 199.9, 1999 0.6 - 125.6 m 0.125 - 1.256, 19.99, 199.9 km Accuracy (5% Reading + 3 digits) (5% Reading + 3 digits) (5% Reading + 3 digits) Low: 200mA Continuity Test (AUTO, RT+, RT- Mode) Range [] Resolution [] Accuracy(*) 0.01 - 9.99 0.01 (2% Reading + 2 digit) 10.0 - 99.9 0.1 (2% Reading + 2 digit) (*) After Test leads calibration Test Current > 200mA DC per R5 (Test leads included) Resolution for Test current 1mA Open Circuit Voltage 4V V0 24V www.Amprobe.com Data Sheet DM-III MULTITEST Power Quality Recorder Specifications (continued) Insulation Test Test Voltage [V] 50 Range [M] 0.01 - 9.99 10.0 - 49.9 50.0 - 99.9 Resolution [M] 0.01 0.1 0.1 Accuracy (2% Reading + 2 digit) (2% Reading + 2 digit) (5% Reading + 2 digit) 100 0.01 - 9.99 10.0 - 99.9 100.0 - 199.9 0.01 0.1 0.1 (2% Reading + 2 digit) (2% Reading + 2 digit) (5% Reading + 2 digit) 250 0.01 - 9.99 10.0 - 199.9 200 - 249 250 - 499 0.01 0.1 1 1 (2% Reading + 2 digit) (2% Reading + 2 digit) (2% Reading + 2 digit) (5% Reading + 2 digit) 500 0.01 - 9.99 10.0 - 199.9 200 - 499 500 - 999 0.01 0.1 1 1 (2% Reading + 2 digit) (2% Reading + 2 digit) (2% Reading + 2 digit) (5% Reading + 2 digit) 1000 Open circuit Test Voltage Short Circuit Current Nominal Test Current 0.01 - 9.99 0.01 10.0 - 199.9 0.1 200 - 999 1 1000 - 1999 1 <1.3 x Nominal Test Voltage <6.0mA with 500V Test Voltage 500V: >2.2mA with 230k; other: >1mA with 1k*Vnom (2% Reading + 2 digit) (2% Reading + 2 digit) (2% Reading + 2 digit) (5% Reading + 2 digit) Frequency Measurement Range [Hz] Resolution [Hz] Accuracy 47.0 - 63.6 0.1 (0.1%Reading+1 digit) RCD and LOOP function are active only for 50Hz 0.5Hz frequency Phase Rotation: Voltage Measurement Range [V] Resolution [V] 0 - 460V 1 Ground Test: Resistance Measurement With Earth Rods Range RE [] Resolution [] 0.01 - 19.99 0.01 20.0 - 199.9 0.1 200 - 1999 1 Accuracy (5% Reading + 3 digit) Test Current <10mA - 77.5Hz Open circuit Test Voltage <20V RM Amprobe(R) Test Tools Accuracy (3%Reading + 2 digit) Data Sheet DM-III MULTITEST Power Quality Recorder Specifications (continued) Ground Test: Resistivity Measurement Range p Resolution 0.60 - 19.99 m 0.01 m 20.0 - 199.9m 0.1m 200 - 1999m 1 m 2.00 - 99.99km 0.01 km 100.0 - 125.6km(*) 0.1 km (*) setting distance = 10m Accuracy (5% Reading + 3 digit) Test Current <10mA - 77.5Hz Open circuit Test Voltage <20V RMS Voltage Measurement - (Autorange) Range [V] Resolution [V] 15 - 310V 0.2V 310 - 600V 0.4V Accuracy (0.5% Reading+2digit) Voltage Sag And Surge Detection - (Manual Range) Range [V] Resolution (Voltage) 15 - 310V 0.2V 30 - 600V 0.4V Resolution (Time) 10ms (_ period) Accuracy (Voltage) (1.0% Reading+2digit) Accuracy (Rif. 50hz) (Time) 10ms (_ period) Input Impedance 300k (Phase-Neutral); 300k (Phase-Phase) Current Measurement - STD & FlexEXTclamps Range [V] Resolution [Mv] 0.005 - 0.26V 0.1 0.26 - 1V 0.4 (*): Example: with a 1000A/1V full scale clamp, the instrument detect only current higher than 5A Accuracy (0.5% Reading+2digit) Input Impedance 200k Overload Protection 5V Current Measurement - FlexINT clamp - 1000A Range Current Range Input Voltage Range 5.00 - 20.00A 425V - 1.7mV 20.00 - 99.99A 1.7mV - 8.499mV 100.0 - 999.9A 8.5mV - 84.99mV Input Impedance 9.166k Overload Protection 5V Resolution 0.850V 0.850V 8.5V Accuracy (4.0%rdg + 8.5V) (1.0% rdg + 8.5V) (1.0% rdg + 85V) www.Amprobe.com Data Sheet DM-III MULTITEST Power Quality Recorder Specifications (continued) Current Measurement - FlexINT clamp - 3000A Range Current Range Input Voltage Range 15.00 - 99.99A 1.27mV - 8.499mV 100.0 - 270.0A 8.5mV - 22.75mV 270.0 - 999.9A 22.75mV - 84.99mV 1.00 - 3.00kA 85mV - 255mV Input Impedance 9.7k Overload Protection 5V Resolution 0.850V 8.5V 8.5V 850V Accuracy (1.0% rdg + 8.5V) (1.0% rdg + 42.5uV (1.0% rdg + 85uV) (0.5% rdg + 8.5mV) Power Measurement - (Autorange) Quantity Range Resolution Active Power 0 - 999.9W 0.1W 1 - 999.9kW 0.1kW 1 - 999.9MW 0.1MW 1000 - 9999MW 1MW Reactive Power 0 - 999.9VAR 0.1VAR 1 - 999.9kVAR 0.1kVAR 1 - 999.9MVAR 0.1MVAR 1000 - 9999MVAR 1MVAR Apparent Power 0 - 999.9VA, 0.1VA 1 - 999.9kVA, 0.1kVA 1 - 999.9MVA 0.1MVA 1000 - 9999MVA 1MVA Active Energy (Classe2 EN61036) 0 - 999.9Wh, 0.1Wh 1 - 999.9kWh, 0.1kWh 1 - 999.9MWh 0.1MWh 1000 - 9999MWh 1MWh Reactive Energy (Classe3 IEC1268) 0 - 999.9VARh, 0.1VARh 1 - 999.9kVARh, 0.1kVARh 1 - 999.9MVARh 0.1MVARh 1000 - 9999MVARh 1MVARh Accuracy (1.0%Reading+2digit) Cos j Measurement Cos J 1.00 - 0.80 0.80 - 0.50 0.50 - 0.20 Resolution Accuracy [] 0.6 0.7 1.0 0.01 Voltage and Current Harmonics Measurement Range Accuracy DC - 25H (5% + 2 digit) 26H - 33H (10% + 2 digit) 34H - 49H (15% + 2 digit) Resolution 0.1V / 0.1A Harmonics values are null under fixed threshold: - DC: its values is null if it is < 2%of Fundamental or is <2% of Full Scale clamp - 1st Current Harmonic: its values is null if it is < 0.2% Full Scale clamp - 2nd - 49th: its values is null if it is < 0.5% of fundamental or is < 0.1% of Full Scale clamp Amprobe(R) Test Tools DM-III MULTITEST Power Quality Recorder Data Sheet Technical Data - General Information General Safety Protection Classification Pollution Degree Degree of Protection Over-Voltage Category Usage EMC EN 61010-1 + A2 (1997) Class 2 - Double Insulation 2 IP50 CAT II 600V Indoor; max height 2000m EN61326-1 (1997) + A1 (1998) The Instrument complies with European Guidelines for CE mark Safety Test Low1/2 (200mA) IEC 61557-4 Insulation Test IEC 61557-2 Phase Sequence IEC 61557-7 Ground Test IEC 61557-5 Power Quality Voltage Sag and Surge EN50160 Alternating Current Static Watt-hour meters for Active Energy EN61036 (CLASS 2) Alternating Current Static VAR-hour Meters for Reactive Energy IEC1268 (CLASS 3) General Specifications Mechanical Data Dimensions 225 (L)x165 (W) x 105 (H)mm Weight 1,2Kg approx Power Supply 6 x 1.5-LR6-AA-AM3-MN 1500 batteries Battery Life Low1/2 ~ 800 test Insulation Test ~ 500 test Ground Test ~ 1000 test Phase Sequence ~ 1000 test ~20 hours Power Quality (recording) External Power Supply Adapter Code DMT-EXTPS (only for POWER QUALITY function) Display Display Type Graphic with Backlight Resolution 128x128 Visible Area 73mmx73mm Memory Safety Test Memory 999 measurement Power Quality 2MByte (with 63 channels select and Integration Period = 15min -> more than 30 days). Environment Reference Temperature 23 5C Working Temperature Range 0 - 40C Working Humidity < 80% Storage Humidity Range -10 - 60C Storage Humidity < 80% www.Amprobe.com Data Sheet Includes Amprobe's Download Suite Software Replacement Parts (supplied with product) DM-CT-HTA HW1254A DMT-EXTPS MTL-VOLT MTL-EARTH C-2001 www.amprobe.com www.amprobe.com 1000A Clamp Soft Carrying case External power supply 12VDC Complete set of voltage and megohmmeter test leads and alligator clips Carrying case containing: 4 earth rods and 4 test leads (banana - alligator clip) Special RS-232 Computer Cable PC Software Instruction Manual Optional Accessories AM-FLEX33 DM-CT-100 RS-USB CC-DM-III 3000A Flexible CT 100A Compact Clamp (0.5A to 100A) USB-RS-232 Adapter Hard Case Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Amprobe(R) Test Tools Europe Amprobe Test Tools Europe Beha-Amprobe GmbH In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2009 Amprobe Test Tools. All rights reserved. 04/2009 3465330 Rev A www.Amprobe.com